Rapid-air AIR FEED / CUT-TO-LENGTH WITH KEYPAD Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware Rapid-air AIR FEED / CUT-TO-LENGTH WITH KEYPAD. Rapid-Air AIR FEED / CUT-TO-LENGTH WITH KEYPAD User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 21
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
RAPID-AIR CORPORATION
4601 KISHWAUKEE ST. ROCKFORD, IL 61109-2925
Phone: (815) 397-2578 • Fax: (815) 398-3887 Web Site: www.rapidair.com
AIR FEED / CUT-TO-LENGTH
WITH KEYPAD
OPERATING INSTRUCTIONS
Vista de pagina 0
1 2 3 4 5 6 ... 20 21

Indice de contenidos

Pagina 1 - OPERATING INSTRUCTIONS

RAPID-AIR CORPORATION4601 KISHWAUKEE ST. • ROCKFORD, IL 61109-2925Phone: (815) 397-2578 • Fax: (815) 398-3887 • Web Site: www.rapidair.comAIR FEED /

Pagina 2

9 Once you have programmed the required parameters. Select the manual mode of operation. After you have verified that the feed and cutter are operat

Pagina 3

10 INTERFACING EXPLANATION A. TAUT STOCK INPUT This is a normally open contact from a switch or device that monitors the loop of material prior to th

Pagina 4

11 OPERATOR INPUT TERMINAL-PROGRAMMING PROCEDURE-STANDARD SOFTWARE The intent of this section is to familiarize the operator with the program flow an

Pagina 5

12 1. When pressing the F4 key the display reverts back to the main menu. 2. All manual keys are now active. Pressing any labeled key will activate

Pagina 6

13 Each time the switch changes state, the screen switches to off or on. If the switch is energized, the screen displays on. If the switch is de-ene

Pagina 7

14 At this time the operator can choose to run auto total or exit. If exit is chosen then the previous screen is displayed. If run is chosen then th

Pagina 8

15 Once the number has been entered, the previous screen appears. Press F2 run current batch and the following screen appears and cycling begins.

Pagina 9

16 PROBLEM The attempt is made to start the machine by pulling the mushroom start button but no lights illuminate. The attempt is made

Pagina 10

17 The attempt is made to cycle the Cutter, but it won’t move. The unit drops out of automatic at random times. The total count counter will not

Pagina 11

18 PROBLEM Feed and stock clamps work, but slide block does not move when actuating valve is depressed. Excessive leakage of air from exhuast hole

Pagina 12

1 Air Feed/Cut-to-Length with Keypad Table of Contents Charts and Drawings Directory pg. 2 Installation

Pagina 13

19 PROBLEM Feed has difficulty pushing last part of progression. Over feeding Under feeding Slide block will move out ok

Pagina 15

2 CHART AND DRAWINGS Programming Map pg. 20 Manual Sequence pg. 21 Auto Seque

Pagina 16

3 Operating Instructions Cut to Length Machine INSTALLATION: The Cut to Length (CTL) that you have just received is fully assembled and ready to be

Pagina 17

4 SMALL CUTTER Cutter Data: See specific cutter specifications. Operations: The solenoid valve, which is remote mounted, is attached to the cutter (

Pagina 18

5 AIR FEED PROGRESSION SET UP The feed guide rollers are adjustable by loosening the machine screws and moving the rollers to the desired position.

Pagina 19 - Rapid-Air Feeds

6 LUBRICATION For a general guide for the Rapid Master, the lubricator oil release adjustment should be set to one drop of oil for each 50-80 strokes.

Pagina 20

7 RECOMMENDED LUBE FOR ASSEMBLY OF RAPID-AIR FEEDS MIXTURE OF LUBRIPLATE AND MOLYKOTE No. 105 Lubriplate Fiske Bros. Refining Co.

Pagina 21

8 ELECTRICAL SET-UP 1. MASTER POWER ON/OFF BUTTON Mushroom push/pull lighted pushubtton. Pull to turn on the power and push to turn off